TM 9-2350-287-20-2 18-29. APU CABLE (12329662) REPLACEMENT (continued). b. INSTALLATION WARNING Adhesives can bum easily, can give off harmful vapors, and are harmful to skin and clothing.  To  avoid  injury  or  death,  keep  away  from  open  fire  and  use  in  a  well- ventilated area. If adhesive gets on skin or clothing, wash immediately with soap and water. NOTE Seal all exposed terminals with sealant adhesive. 1. Install connector (6) of ground lead (5) to wiring harness connector (7). 2. Install ground lead (5) on terminal E (4). 3. Install washer (2) and self-locking nut (1) on terminal E (4) of generator terminal box (3). FOLLOW-ON MAINTENANCE: . Install air intake plenum (para 18-17). . Connect battery cables (para 7-41). 18-75/(18-76  blank)