TM   9-2350-287-20-2 18-28.   APU   WIRING   HARNESS   (12329660),   FUEL   SOLENOID   TO   HOUR   METER REPLACEMENT  (continued). 6. 7. b. 1. 2. 3. 4. 5. 6. Remove two screws (11), Iockwashers (12) and clamps (9) from wiring harness (10). Remove wiring harness (10) from APU. INSTALLATION Install wiring harness (10) on APU. Install two clamps (9) on wiring harness (10) with two screws (11) and new lock- washers  (12). Connect harness BZ (6) connector and harness BY (2) connector to APU hour meter (8). Connect harness Connect harness BZ (6) to fuel solenoid (7). BY (2) to fuel solenoid (7). Install washer (3), new Iockwasher (4), and nut (5) to each fuel solenoid (7) terminal. 18-72