17-18.  CONVEYOR  TOGGLE  CLAMP  AND  TUBE  ASSEMBLY  REPAIR  (continued). 3. Remove screw (10), Iockwasher (9), washer (8), and tube assembly (2) from takeup-end-section assembly (7).  Discard  Iockwasher. b. 1. 2. 3. 4. DISASSEMBLY Remove screw (14), nut (11), Iockwasher (12), washer (13), and hook (3) from clevis (15). Discard Iockwasher. Remove clevis (15) from toggle clamp (6). Remove screw (21), washer (20), clevis (18), and brace (19) from rod end (1 7). Back off jam nut (16), and remove rod end (17) and jam nut (16) from tube assembly (2). 17-44 TM  9-2350-287-20-2