TM 9-2350-287-20-2
17-8. DEAD-END SECTION ASSEMBLY REPAIR (continued).
d.
INSTALLATION
NOTE
Step 1 applies to both dead-end section assemblies.
1.
Position either dead-end section assembly (1 or 5) in alinement with adjoining conveyor section (14).
NOTE
Steps 2 and 3 apply only to rear dead-end section assembly.
2.
Route conveyor electrical wiring harness (13) into place on rear dead-end section assembly (5), and secure
with three straps (9), washers (8), new Iockwashers (7), and screws (6).
3.
Connect two ground leads (10) to override safety switch (11) and deadman switch (12).
NOTE
Step 4 applies to both dead-end section assemblies.
4.
Install connecting link (2) and two washers (3) and new cotter pins (4) at both ends on rear or forward dead-
end section assembly (1 or 5).
FOLLOW-ON MAINTENANCE:
l Stow conveyor (refer to TM 9-2350-287-10).
17-19
|