17-8. DEAD-END SECTION ASSEMBLY REPAIR (continued).
6.
7.
8.
9.
10.
Sealing compound can burn easily, can give off harmful vapors, and are harmful to
skin and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. if seailng compound gets on skin or clothing, wash immediately with
soap and water.
NOTE
Steps 6 through 10 apply only to both dead-end section assemblies.
Apply sealing compound to threads of 20 screws (30).
install two wear strips (29) on either dead-end section assembly (1 or 5) with 20 screws (30).
Install flipper block (28) on either dead-end section assembly (1 or 5) with support bar (31).
Install two washers (32) and new cotter pins (33) on support bar (31).
Secure flipper block (28) to support bar (31) with two setscrews (34).