TM 9-2350-287-20-2
15-84. PROJECTILE RACK ASSEMBLY BRACES REPLACEMENT (continued).
b.
INSTALLATION
1.
Install two braces (7 and 16) on angle (8) with four screws (11), new Iockwashers (10), and washers (9).
2.
Install angle (8) on middle top door (15) with three screws (12), new Iockwashers (13), and washers (14).
3.
Adjust two brackets (7 and 16) and angle (8) on middle top door (15) to provide snug fit on projectile rack
assemblies (5 and 6).
4.
Install brace (4) on angle (3) with two screws (19), new Iockwashers (18), and washers (1 7).
5.
Install angle (3) and spacer (2) on outside APU compartment wall (1) with two screws (20), new Iockwashers
(21), and washers (22).
6.
FOLLOW-ON MAINTENANCE:
l None
15-210
Adjust brace (4) to provide snug fit on projectile rack assemblies (5 and 6).
|