TM 8-2350-287-20-1
9-2. BREATHER TUBE, FILTER, AND MOUNT REPLACEMENT (continued).
a.
REMOVAL
1.
Loosen nut on hose (3) and remove hose (3) from elbow (4).
2.
Remove breather filter (6) from breather mount (7).
3.
Remove two screws (11), Iockwashers (10), and washers (9) and ground lead (12) from transmission (8).
Discard Iockwashers.
NOTE
Breather tube can be replaced without removing mount.
4.
Disconnect two fittings (2) on breather tube (5) at elbow (1) and mount (7).
5.
Remove breather tube (5) and mount (7) from transmission (8).
b.
INSTALLATION
Do not tighten screws until after tube is connected.
1.
Install mount (7) and breather tube (5) on transmission (8).
2.
Install ground lead (12) and two screws (11), new Iockwashers (10), and washers (9) on transmission (8) and
connect two fittings (2) on breather tube (5) at elbow (1) and mount (7).
3.
Tighten two screws (11) on mount (7).
4.
Install breather filter (6) on mount (7).
5.
Install hose (3) on elbow (4) and tighten nut on hose (3).