7-28. REMOTE CHEMICAL DETECTOR ALARM TERMINALS REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
Initial Setup:
Tools/Test Equipment:
Equipment Conditions:
l General mechanics tool kit (Item 24,
l Vehicle parked on level ground
Appendix I)
(refer to TM 9-2350-287-10).
l MASTER switch set to OFF
Materials/Parts:
(refer to TM 9-2350-287-10).
l Lockwasher (Item 118, Appendix H)
l Disconnect battery ground cables
l Nonmetallic washer (2) (Item 208, Appendix H)
(para 7-41).
a.
1.
2.
3.
4.
b.
1.
2.
3.
4.
NOTE
There are two pairs of terminals. Each pair is installed on a vehicle-mounted bracket.
Each terminal is removed and installed in the same way. These procedures cover
only one terminal.
REMOVAL
Remove nut (10) and Iockwasher (9) from terminal
(1). Discard Iockwasher.
Remove cable connector (8) from vehicle-mounted
terminal bracket (5).
Remove washer (7) and nonmetallic washer (6)
from terminal (1). Discard nonmetallic washer.
Pull terminal (1) out of terminal bracket (5) along
with nonmetallic washer (3) and two washers (2
and 4). Discard nonmetallic washer.
INSTALLATION
Install terminal (1) on terminal bracket (5) using
two washers (2 and 4) and new nonmetallic washer
(3).
Install nonmetallic washer (6) and washer (7) on
terminal (1).
Install cable connector (8) on terminal bracket (5).
Install nut (10) and new lockwasher (9) on terminal
(1).
FOLLOW-ON MAINTENANCE:
l Connect battery ground cables (para 7-41).