TM 9-2350-287-20-1
6-7.
AERATION DETECTOR REPLACMENT (continued).
b.
DISASSEMBLY
1.
Remove adapter (21) and elbow (22) from aeration detector (20).
2.
Remove adapter (24) from aeration detector (20).
3.
Remove two screws (26) and cover (25) from aeration detector (20).
4.
Remove three screws (27), wire connectors (28), and washers (29) from aeration detector (20).
c.
INSPECTION
Inspect wiring harness (24) for cracks, breaks, or fraying. Replace as necessary.
d.
ASSEMBLY
1.
Install three wire connectors (28), screws (27), and washers (29) on aeration detector (20).
2.
Install cover (25) and two screws (26) on aeration detector (20).
Change 1 6-17