3.
Remove nut (9), washer (8), and strap (7) from box assembly on side of air duct.
4.
Remove three air inlet ducts and hoses (6) (para 4-9).
5.
Disconnect STE/ICE wiring harness (15) from pressure transducer (14).
6.
Remove five self-locking nuts (10) and washers (11 ), clamp (12), and STE/lCE wiring harness (15) from front
of air cleaner duct (13). Discard self-locking nuts.
7.
Remove 23 self-locking nuts (23) and washers (22) from studs on inside lip of air cleaner duct (1 3).
self-locking nuts.
8.
Disconnect pressure indicator hose (20) from adapter (21 ) under left side of air cleaner duct (1 3).
WARNING
Air cleaners must be supported by a crowbar when removing screws, to prevent
possible injury to personnel or damage to air cleaner.
NOTE
There are two air cleaners. An assistant is required when removing air cleaners.
Left air cleaner must be removed first. Both air cleaners must be removed before
removing air cleaner duct.
Both air cleaners are removed in the same manner unless noted otherwise. Removal
of right air cleaner is shown.
9.
Support air cleaner (19) with crowbar.
Discard
4-22