TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
v. AFES, ENGINE (continued).
(1) POWER ON LAMP DOES NOT LIGHT WHEN
MASTER SWITCH IS ON. All other electrical
systems operate (continued).
C. 2. Disconnect wiring harness 12351461, wire
10A from circuit breaker No. 6 on circuit breaker
panel No. 2.
3. Place red lead of multimeter in circuit breaker
socket and ground black lead of multimeter.
4. Check for 24 ± 3 vdc.
Repair wire 10A or replace wiring
harness 12351461 (para 7-79).
Verify problem is solved.
D. Connect wiring harness 12351461, wire 10A
to circuit breaker No. 6 on circuit breaker
panel No. 2.
2. Disconnect wiring harness 12351754 wire
10 from circuit breaker No. 6 on circuit breaker
panel No. 2.
3. Place red lead of multimeter in wire 10
connector and ground black lead of multim-
eter.
4. Check for 24 ± 3 vdc.
Replace circuit breaker No. 6 (para
E. 1. Connect wiring harness 12351754 wire
10 connector to circuit breaker No. 6 on
circuit breaker panel No. 2.
Continued on next page
7-11). Verify problem is solved.
2-324