TM 9-2350-287-20-1
2-19. TROUBLESHOOTING CHART (continued).
j.
AUXILIARY OUTLET (continued).
(1) AUXILIARY OUTLET FAILS TO OPERATE. All other
electrical systems operate (continued).
CONTINUED FROM B
B.
4. Turn MASTER switch ON (refer to TM 9-
2350-287-1 0).
5. Check for 24 + 3 vdc.
6. Turn MASTER switch OFF (refer to TM 9-
2350-287-1 O).
Is voltage indicated?
Replace auxiliary outlet (para
7-9). Verify problem is solved.
c.
NOTE
For the following steps (C&D),
the drivers instrument panel
needs to be removed (refer to
TM 9-2350-287-10).
1. Reconnect lead 37 of harness 12330252
to auxiliary outlet.
2. Disconnect harness 12330252 lead 37/38
from circuit breaker no. 1, panel no. 1.
3. Place multimeter red Iead on circuit breaker
no. 1 connector pin and ground black lead.
4. Turn MASTER switch ON (refer to TM 9-
2350-287-10).
5. Check for 24 + 3 vdc.
6. Turn MASTER switch OFF (refer to TM 9-
2350-287-10).
Is voltage indicated?
Continued on next page
2-214