TM 9-2350-287-20-l
2-19. TROUBLESHOOTING CHART (continued).
f.
GENERATOR (continued).
(1) GENERATOR FAILS TO CHARGE BATTERIES.
GAGE INDICATES NOT CHARGING, UNSTEADY,
OR INACCURATE READING (continued).
CONTINUED FROM A
Repair faulty wires or replace harness
12268308 (para 7-50). Verify problem IS
B. 1. Reconnect wire harness 12268308 to al-
ternator.
2. Remove wires 1 and 3 from harness
12268308 rectifier connector.
3. Connect wire harness 12268308 to recti-
fier.
4 Turn MASTER switch ON and start en-
gine (refer to TM 9-2350-287-1 O).
5. Set multimeter to AC and place multim-
eter red lead on pin of wire 1, ground black
lead, and check for 28* 3.
6. Repeat step 4 for wire 3 pin.
7. Turn engine and MASTER switch OFF
(refer to TM 9-2350-287-1 O).
s voltage indicated?
Replace generator (alternator) (para
7-2). Verify problem is solved.
Continued on next page
2-89
solved.