TM 9-2350-287-20-1
I
2-19. TROUBLESHOOTING CHART (continued).
d. ENGINE, ELECTRICAL SYSTEM (continued).
(2) ENGINE CRANKS SLOWLY, BATTERY lNDlCA-
TOR IN LOW YELLOW OR RED.
Initial Setup:
Tools/Test Equipment:
MASTER switch set to OFF (refer to
General mechanics tool kit (Item 24,
TM 9-2350-287-10).
Appendix I)
STE/lCE test equipment (Item 65, Appendix I)
Equipment Conditions:
Equipment and transmission access doors open
(refer to TM 9-2350-287-10).
A. Perform STE/ICE troubleshooting, CHARG-
ING CIRCUIT (at battery) - TEST 67 (para 2-
22 b. (8)).
Does test pass?
Recharge or replace batteries (para
7-41 ). Veril problem is solved.
Go to Electrical troubleshooting
GENERATOR FAILS TO CHARGE
BATTERIES. GAGE INDICATES NOT
CHARGING (para 2-19 f. (l)).
END OF TASK
2-61