TM 9-2350-287-10
AIR CLEANER MAINTENANCE (continued)
8. Pull down locking handles (5). Push two air filters (6) in, lift, and pull out from air cleaner box.
WARNING
Compressed air used for cleaning purposes should not
exceed 30 psi (206.8 kPa). Use compressed air only with
effective chip-guarding and personal protective equipment
(e.g., goggles/shield, gloves). Failure to do this may result in
injury to personnel.
9.
Clean air filters (6) with compressed air. (Emergency clean
by rapping bottom or sides of air filter against flat surface.
Do not strike open edge or sealing edge.)
10.
Clean air filter compartments with damp rags (Item 40,
Appendix D).
11.
Clean air duct into air filter box with damp rags (Item 40,
Appendix D) as far as possible.
12.
Check seal (7) on right and left access doors (4 and 1) for
damage or unserviceable condition. If seal is damaged or
in unserviceable condition, notify Unit maintenance.
13.
Replace air filters (6); aline with outlet gaskets to assure
proper sealing, and secure locking handles (5).
14.
Slide right and left access doors (4 and 1) on air cleaner,
and secure doors by pulling locking latch (2) down and then
up.
15.
Reset air cleaner restriction indicator (8) by pushing up on
reset button (located on bottom of cylinder).
16.
Start engine (p. 2-82). f yellow sleeve in indicator (8) climbs
into red zone, notify Unit maintenance.
17.
Install right projectile rack assembly (p. 2-1 85)
3-28