3.
Install four straps (16) on tray (4), secure with sixteen screws (13), thirty-two washers (15), and new locknuts (14).
4.
Install tray (4) on four resilient mounts (12) and secure with four screws (10) and new lockwashers (11).
5.
Install mount (3) on inverter (5) and secure with four screws (7), washers (8), and new locknuts (9).
6.
Install mount (3) and inverter (5) in housing (6), secure on tray (4) with three screws (1) and new lockwashers (2). Have
Helper assist.