TM 9-2350-277-34
INSTALL PERSONNEL HEATER KIT (M1064A3 ONLY) Continued
0073 00
8.
Secure plenum (1) to personnel heater (2) with four lockwashers (3) and screws (4).
9.
Secure two saddles (5) to two brackets (6) with four screws (7), three lockwashers (8), ground strap (9), and four
locknuts (10).
10. Install two clamps (11) on two saddles (5).
11. Install clamp (12) on heater air intake pipe (13) and clamp (14) on heater exhaust port (15).
12. Install elbow (16) on heater air intake pipe (13) and air intake elbow (17).
13. Position heater (2) and shield (18) on two saddles (5), and secure with two clamps (11). Ensure air intake and exhaust
fittings are properly aligned.
14. Tighten clamp (14) on heater exhaust port (15) and exhaust pipe in carrier.
15. Tighten clamp (12) on heater air intake pipe (13).
16. Secure ground strap (9) to heater (2) with two lockwashers (19) and existing screw (20).
17. Discard front three screws (21) and washers (22) removed with floor plates.
18. Secure fuel pump (23) to hull bracket (24) with four lockwashers (25) and two screws (26).
NOTE
Shielded lead must be secure to bracket to ensure complete grounding and proper operations of
fuel pump.
19. Secure pump lead (27) to hull bracket (24) with two lockwashers (28), one screw (29), and locknut (30).
0073 00-3