TM 9-2350-277-20-6
REPLACE/REPAIR VFM POWER DISTRIBUTION PANEL ASSEMBLY (M981A3 ONLY)
Continued
0913 00
3.
Disconnect lead (10) from switch S1 (11).
4.
Disconnect lead (12) from circuit breaker CB2 (13).
5.
Disconnect lead (14) from circuit breaker CB3 (15).
6.
Disconnect lead (16) from connector J1 (17).
7.
Disconnect lead (18) from connector J2 (19).
8.
Disconnect lead (20) from circuit breaker CB4 (21).
9.
Disconnect lead (22) from connector J3 (23).
10. Remove two screws (1) lockwashers (2), clamps (3), and heater cable (4) from hull. Discard lockwashers.
0913 00-3