TM 9-2350-277-20-5
REPLACE M8A3 NBC AIR PURIFIER AND FRAME (M1059A3 ONLY) Continued
0777 00
5.
Loosen screw (12) on shock mount (6). Slide slotted end of ground cable (15) under screw (12). Tighten screw.
6.
Install air purifier (17) in frame (11). Secure with latch (18).
7.
Attach quick-disconnect fittings of hoses for drivers station (19), commanders station (20), and smoke operators
station (21) to air purifier (17).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00).
2.
Adjust air purifier. See TM 3-6680-316-10 for procedure.
3.
Start engine (see your -10).
4.
Raise and lock ramp (see your -10).
5.
Stop engine (see your -10).
END OF TASK
0777 00-3/4 blank