TM 9-2350-277-20-5
REPLACE SMOKE GENERATOR CONTROL PANEL ASSEMBLY (M1059A3
ONLY)
0756 00
THIS WORK PACKAGE COVERS:
Removal (page 0756 00-1).
Installation (page 0756 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Lockwasher (12)
Locknut (4)
Personnel Required
Unit Mechanic
References
See your -10
TM 3-1040-283-10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Circuit breaker CB1 OFF (TM 3-1040-283-10)
Battery ground strap disconnected (WP 0337 00)
WARNING
Before you do any maintenance, discharge all capacitors to ground or electrical shock could
injure personnel.
REMOVAL
NOTE
Tag all cables to match their respective connectors before removal.
1.
Disconnect six cable assembly plugs (1) from control panel (2). Install associated dust caps (3).
2.
Remove four screws (4), lockwashers (5), eight washers (6), four locknuts (7), and control panel (2) with two attached
brackets (9) and (11) from two brackets (8) and (10). Discard lockwashers and locknuts.
3.
Remove eight screws (12), lockwashers (13) and two brackets (9)(11) from control panel (2). Discard lockwashers.
0756 00-1