TM 9-2350-277-20-5
REPLACE COOLANT HEATER FUEL INLET HOSE AND FITTINGS Continued
0712 00
INSTALLATION
1.
Apply light coat of sealing compound to tapered threads of elbows (2) and (8) nipple (9).
2.
Install nipple (9) in shutoff valve (10).
3.
Install elbow (8) on nipple (9).
4.
Install inlet hose (3) on elbow (8).
5.
Install five clamps (7) on hose (3).
6.
Install elbow (2) and jamnut (4) in bulkhead. Install hose (3) on elbow (2).
7.
Align five clamps (7) on hull weldnuts. Secure with five screws (5) and two nuts (6).
8.
Install supply hose (1) on elbow (2).
0712 00-3