TM 9-2350-277-20-5
REPAIR HYDRAULIC RESERVOIR Continued
0672 00
4.
Install new preformed packing (12) and adapter (13) on side of reservoir (11).
5.
Apply sealing compound to the male threads of the breather (14).
6.
Install breather (14) in top of reservoir (11).
7.
Install fill plug (15) and new preformed packing (16).
8.
Install liquid indicator sight (17) and new preformed packing (18).
9.
Install elbow (19), new preformed packing (20), and cap (21).
FOLLOW-THROUGH STEPS
1.
Install hydraulic reservoir (WP 0671 00).
END OF TASK