TM 9-2350-277-20-3
REPLACE NATO AUXILIARY POWER (SLAVE) RECEPTACLE (M577A3 AND M1068A3
ONLY) Continued
0264 00
4.
Pull receptacle (12) and adapter (13) away from hull.
5.
Remove screw (14), lockwasher (15), and circuit 6 lead (16) from positive terminal of receptacle (12). Discard
lockwasher.
6.
Remove screw (17), lockwasher (18) and circuit 50 lead (8) from negative terminal of receptacle (12). Discard
lockwasher.
7.
Remove four screws (19), lockwashers (20), and washers (21) from adapter (13). Discard lockwashers.
8.
Remove receptacle (12), gasket (22), insulator (23), adapter (13), and gasket (24) from hull. Discard gaskets.
9.
Remove insulator bushing (25) from hull.
0264 00-2