TM 9-2350-277-20-3
REPLACE VENTILATION FAN (M577A3 AND M1068A3 ONLY)
0383 00
THIS WORK PACKAGE COVERS:
Removal (page 0383 00-1).
Installation (page 0383 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Locknuts (6)
Locknuts (3)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery access cover removed (see your -10)
Battery ground lead disconnected (WP 0338 00)
Power plant rear access panel removed (see your -10)
REMOVAL
1.
Disconnect blower lead (1) from circuit 59 lead (2).
2.
Remove six locknuts (3), washers (4), screws (5), and adapter (6) with blower (7) attached, from flapper valve (8).
Discard locknuts.