TM 9-2350-277-20-3
REPAIR WIRING HARNESS Continued
0382 00
e.
Heat shrink those leads with insulated sleeving (1) on terminal (2).
4.
Install multiple connectors the same way as single connectors. See Step 1 and Step 2 above.
5.
If removed, install Y-type adapters and dummy plugs.
a.
Install Y-type adapter (3) on harness leads (4).
b.
Install dummy plugs (5) in male or female connector (6).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).
2.
Turn MASTER SWITCH to ON (see your -10).
3.
Check for proper wiring harness repair.
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0382 00-6