TM 9-2350-277-20-3
REPLACE BATTERY LEADS AND TERMINALS (M58 ONLY) Continued
0345 00
1.
Remove cable mounting nuts (1) and bolts (2) from each battery terminal adapter (3) on four batteries (4)(5)(6)(7).
2.
Remove two battery positive-to-negative cables (8) and (9) from battery box.
3.
Remove STE/ICE circuit 779 lead (10) from battery box.
4.
Remove vehicle power cable (11), shunt cable (12), smoke obscurant system master power relay lead 6W21 (13), and
STE/ICE circuit 772/778 leads (14) from battery box.
5.
Remove positive communication power cable (15) and negative communication power cable (16) from battery box.
6.
Remove one battery positive-to-positive cable (17) and one battery negative-to-negative cable (18) from battery box.
0345 00-2