TM 9-2350-277-20-3
REPLACE BILGE PUMP CIRCUIT BREAKERS (ALL EXCEPT M981A3)
0275 00
THIS WORK PACKAGE COVERS:
Removal (page 0275 00-1).
Installation (page 0275 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Locknut (8)
Locknut (4)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground strap disconnected (WP 0337 00) or
(WP 0338 00)
Instrument warning light panel removed (WP 0260 00)
REMOVAL
1.
Remove eight screws (1), washers (2), and locknuts (3) from master switch panel (4) and distribution box (5). Remove
master switch panel from distribution box. Discard locknuts.
2.
Disconnect circuit 450 lead (6) and circuit 450A lead (7) from front bilge pump circuit breaker (8).
3.
Disconnect circuit 450B lead (9) and circuit 450C lead (10) from rear bilge pump circuit breaker (11).
0275 00-1