TM 9-2350-277-20-3
REPLACE DISTRIBUTION BOX ASSEMBLY (M901A3 ONLY) Continued
0272 00
4.
Remove circuit 2A lead (1) and grommet (2) from distribution box (3).
5.
Remove circuit 2 lead (4) and grommet (5) from distribution box (3).
6.
Disconnect circuit 450 lead (6) from circuit breaker (7). Remove circuit 450 lead and grommet (8) from distribution
box (3).
7.
Disconnect circuit 450B lead (9) from circuit breaker (10). Remove circuit 450B lead and grommet (11) from
distribution box (3).
NOTE
If bilge pump circuit breakers are to be removed, see (WP 0270 00) for removal. If the bilge
pump circuit breakers are not to be removed, go to Step 11.
8.
Remove screw (12), lockwasher (13), and circuit 450C lead (14) from bus bar (15). Discard lockwasher.
9.
Disconnect circuit 450C lead (14) from circuit breaker (16). Remove circuit 450C lead from distribution box (3).
10. Disconnect circuit 450A lead (17) from circuit breaker (18). Remove circuit 450A lead from distribution box (3).
11. Remove circuit 400 lead (19) and grommet (20) from distribution box (3).
0272 00-2