TM 9-2350-277-20-2
REPLACE GLOW PLUG POWER HARNESS
0211 00
THIS WORK PACKAGE COVERS:
Removal (page 0211 00-1).
Installation (page 0211 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Lockwasher (3)
Tie straps (as required)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Drivers power plant access panel
removed (see your -10)
Rear power plant access panel removed (see your -10)
Battery ground strap disconnected (WP 0337 00),
(WP 0338 00), or (WP 0339 00)
REMOVAL
1.
Remove nut (1), lockwasher (2), and red double lead (3) from battery terminal (4) on solenoid (5). Do not remove other
leads. Reinstall nut on battery terminal. Discard lockwasher.
2.
Remove nut (6), lockwasher (7), and orange switch lead (8), from switch terminal (9) on solenoid (5). Do not remove
other leads. Reinstall nut on switch terminal. Discard lockwasher.
3.
Remove nut (10), lockwasher (11), and blue ground lead (12) from ground terminal (13) on solenoid (5). Do not remove
other leads. Reinstall nut on ground terminal. Discard lockwasher.
0211 00-1