TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
Table 19. Annual Unit Level Preventive Maintenance Checks and Services for M113A3 FOV
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
105
Annual
0.1
Carrier
a. Lubricate tachometer and speedometer shafts
annually with GIA. See Tachometer and
Speedometer Shaft Lubrication Table (Table 11,
page 0155 00-26).
1) Disconnect shafts at both ends
(WP 0432 00), remove slotted washers from
drive ends of cores, and remove cores from
instrument panel end of shafts. Clean and
lubricate cores with GIA, insert cores in
shafts. Install slotted washers, and connect
both end of shafts. If tachometer adapter
has a grease fitting, lubricate sparingly with
lubricant GIA.
b. Clean, inspect and lubricate cores. Insert cores
in shafts. Install slotted washers and connect
both ends of shafts. If tachometer adapter has a
grease fitting, lubricate sparingly with GIA.
SPEEDOMETER
SHAFT
TACHOMETER
SHAFT
0155 00-175