TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
85
Semi-
Annual
Tents and
Stowage
Brackets
(M577A3 &
M1068A3 Only)
a. Replace tent that has tears, breaks, fraying, or
other damage (WP 0627 00), (WP 0628 00), and
TM 10-5410-229-13&P.
b. Tighten screws on mounting clamps and strip.
86
Semi-
Annual
4.2 KW
Generator Set
Enclosure
(M577A3 and
M1068A3 Only)
a. Tighten or replace loose or missing screws on
enclosure to 55-60 lb-ft (75-81 N m) torque.
Use torque wrench (WP 0926 00, Item 82).
b. Replace damaged enclosure (WP 0674 00).
0155 00-137