TM 9-2350-277-20-2
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING
LUBRICATION INSTRUCTIONS Continued
0155 00
ITEM
NO.
INTERVAL
MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
CREWMEMBER
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE
IF:
1) Remove drivers power plant access panel
(see your -10).
2) Place suitable container under primary fuel
filter. Open drain cock and drain water and
sediment from primary fuel filter. When
clean fuel starts to drain out, close drain
cock.
3) Repeat Step 67b2 for secondary fuel filter.
4) Check for fuel leaks at primary and
secondary fuel filters while engine is
running. If leak is found, remove and install
primary and secondary fuel filter elements
and check for proper fit and seal
(WP 0202 00).
0155 00-114