TM 9-2350-277-20-1
NO LAN OUTPUT FROM DATA PANEL A12 (M1068A3 ONLY)Continued
0111 00
T
1. Remove cable W108 plugs P1 (1) and P2 (2) from Data Panel
A12 jacks J107 (3) and J108 (4).
2. Remove cable W107 plugs P1 (5) and P2 (6) from Data Panel
A12 jacks J105 (7) and J106 (8).
3. Measure resistance between center pins of plugs P1 and P2 of
each cable.
4. Does multimeter read 0 ohms for each measurement?
YES
NO
TN
1. Replace cable W107 and/or W108
(WP 0819 00).
2. Verify no faults found.
0111 00-2