APU CONTROL BOX TO APU VOLTAGE REGULATOR CABLE ASSEMBLY (12330248): REMOVAL, DISASSEMBLY, ASSEMBLY AND INSTALLATION
CONTINUED)
J
K
L
M
Connect APU voltage regulator generator plug (14) to APU voltage
r e g u l a t o r.
Install four nuts (13), four flat washers (12), four new lockwashers (11),
four screws (l0) and receptacle (9) to APU bulkhead. Connect receptacle
(9) to APU electrical disconnect.
Connectable connector (7) to cable assembly 12330256 regulator ground
circuit (8).
Install four nuts (6), four flat washers (5), four new lockwashers (4), four
screws (3) and APU electrical disconnect (2) to APU bulkhead. Connect
APU electrical connector (2) to cable assembly (1).
6-117
Change 4
TM 9-2350-267-20