5-30
TM 9-2350-267-20
HOSES AND TUBES: REMOVAL AND INSTALLATION (CONTINUED)
REMOVAL
Remove in sequence of illustration.
LEGEND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Elbow (3)
Elbow (2)
Adjustable clamp (13)
Hose, surge tank-to-radiator vent
Hose, surge tank-to-relief valve
Adapter (3)
Pressure relief valve
Clamp
Screw
Flat washer
Lockwasher
Hose, surge tank-to-radiator
Hose, surge tank-to-bypass tube
29 Engine coolant manifold connector housing
30 Bypass tube
31 T-connector bypass tube
32 Inlet thermostat housing assembly
33 Radiator filler tube with two vents
34 Hose, radiator vent-to-bypass tube
35 clamp (2)
36 Screw
37 Flat washer
38 Lockwasher (2)
39 Aeration detector assembly tubing
INSTALLATION
Hose, surge tank-to-tube 12 (to main tube)
Tube, hose 12-to-hose 19 (to main tube)
A
Screw
Clamp
B
Lockwasher
Nut
Clamp (2)
C
Screw
Lockwasher
Hose, tube 13-to-main tube
D
Main tube
clamp (33)
E
Connector hose (9)
Engine coolant lower tube
Outlet thermostat housing assembly
Reverse removal procedures.
Apply adhesive (item 1, Appx D) to ends of tubes and hoses
before assembly.
Replace gaskets at inlet and outlet thermostat assemblies if
engine coolant manifolds are disconnected.
Torque all tube/hose connector clamps to 40-60 lb-in.
Install power plant (p 3-1) and refill radiator (22 gal) with
coolant (TM 9-2350-267-10).
TA310322