AIR CLEANER: REMOVAL, DISASSEMBLY, ASSEMBLY AND INSTALLATION (CONTINUED)
Disconnect STE/ICE wiring harness (24) and remove transducer
(25) under air cleaner duct (26).
Remove five nuts (27), five flat washers (28) and STE/ICE
harness clamp (29) from stud (30).
Remove eight screws (31), eight lockwashers (32) and eight flat
washers (33). Discard lockwashers.
Remove 2 x 4 supports and lower boxes (34 and 35) and duct
(26) to hull deck.
From inside of air cleaner duct (26) remove 23 nuts (27) and 23
flat washers (28) from studs (30).
Remove left air cleaner box (35), air cleaner duct (26) and right
air cleaner box (34).
Disconnect pressure indicator hose (3) from adapter (36) under
left side of air cleaner duct (26).
TA57134
4-26.1
Change 2
TM 9-2350-267-20