2-188
TM 9-2350-267-20
R Disconnect harness 12351461 plug from ventilation blower
motor connector. Turn MASTER switch ON. Check continui-
ty between plug sockets B and C. If continuity is not indicated,
replace electrical harness 12351461 (p 6-93).
s
Turn MASTER switch OFF. Disconnect harness 12351461 plug
(circuits 159, 48, 159) from accessory control box. Check voltage.
Place red probe of multimeter in socket A of accessory control
box connector, and ground black probe. Turn MASTER switch
ON. If voltage is not indicated, troubleshoot accessory control
box circuitry (p 6-26). If voltage is indicated, replace electrical
harness 12351461 (p 6-93).
TA310547