2-174
TM 9-2350-267-20
c
Reconnect harness at accessory control box. Disconnect wir-
ing harness and personnel heater. MASTER switch ON, HEAT
SELECTOR switch LOW. Place red lead of multimeter in
socket C (wire 402) and black lead to ground. Check for voltage.
Repeat voltage check on socket D (wire 405). If voltage is not
present in both wires, repair or replace defective wires
(p 6-100). If voltage is present reconnect harness and troubleshoot
personnel heater circuitry (TM 9-2540-205-24&P).
D
Remove accessory control box (p 6-26). Remove cover and
disconnect wire 10 from circuit breaker. Place MASTER switch
ON. Place red lead of multimeter in wire 10 connector and black
lead to ground. If voltage is not present, replace wire 10 in ac-
cessory control box (p 6-26). If voltage is present, go to step E.
TA310533