2-122
Change 1
TM 9-2350-267-20
B
Check wire 81 for breaks, cuts and corroded terminals. Replace
if necessary (p 6-68). Disconnect wire 82 from master relay.
Place red multimeter lead in master relay and ground black lead.
Check voltage. If no voltage, replace master relay (p 6-45). If
voltage is present, reconnect and go to step C.
c
Disconnect wire 49 at bulkhead disconnect. Place red
multimeter lead in wire 49 and black lead to ground. Check for
voltage. If voltage is not present, replace wire 49 from master
relay to bulkhead (Appx F). If voltage is present, reconnect and
go to step D.
TA312699