PERSONNEL HEATER: REMOVAL AND INSTALLATION (CONTINUED)
INSTALLATION
F
A
B
C
D
E
Position personnel heater (12) and connect exhaust tube (7). Torque nut (6)
to 65-75 lb-in.
Secure personnel heater (12) with two clamps (11).
Screw nut (8) onto elbow (9) to connect fuel line (10).
Connect hose (5). secure Clamp (4).
Connect hose (3). secure clamp (2).
Connect electrical connector (1).
WARNING
In case of fire, AFES system must be manually activated
Check operation of personnel heater (TM 9-2350-267-10).
Re-torque nut (4) to 65-75 lb-in.
Install fire extinguisher mountings #1 and #3 (p 14-30).
Install fire extinguisher bottles #1 and #3 (p 14-28).
14-68.3/(14-68.4 blank)
Change 4