M2A2 AIR PURIFIER: REMOVAL, DISASSEMBLY, CLEANING, INSPECTION AND REPAIR, ASSEMBLY, AND INSTALLATION (CONTINUED)
INSPECTION AND REPAIR
A Inspect housing for damage and replace if damaged.
B Inspect manifold air outlet sockets and socket packings for damage. Replace
manifold if damaged.
C Inspect falters for damage and replace if damaged.
ASSEMBLY
A
B
C
NOTE
Make sure filter rests against bulkhead inside housing.
Install particulate filter (6) in housing (3) so air will flow through it in
direction marked on falter housing.
NOTE
Make sure felt gasket side of gas filter is toward manifold
assembly end of purifier.
Install gas falter (5) in housing (3) so it rests on gasket of particulate filter (6)
surface.
Install manifold (4) in housing (3) with four screws (1) and four new
lockwashers (2).