REMOVAL
A
B
WARNING
s Make sure all systems are shut down and
MASTER switch if OFF. Hydraulic fluid may
be HOT.
l Do not perform removal procedures until backup
hydraulic gage has been visually checked. Gage
must show O psi.
CAUTION
Cap hydraulic lines and ports immediately after
disconnecting to prevent contaminants from enter-
ing hydraulic system and hydraulic components.
NOTE
Note location of sprocket on motor shaft to ensure
proper assembly.
Loosen setscrew (1) and remove sprocket
hydraulic motor (3).
Remove key (4) from shaft of motor (3).
(2) from shaft of
C
D
E
F
G
H
I
J
K
NOTE
Note location and routing of hoses before removal
to ensure proper installation.
Disconnect hose (5) from elbow (6).
Disconnect two hoses (7) from two elbows (8) and reducers (9).
Remove two reducers (9), two nuts (10) and two sleeves (11) as
assemblies from two tee assemblies (12) by turning nuts (13).
Remove two nuts (13) and pull two tee assemblies (12) from sup-
port bracket (14).
While helper holds hydraulic motor (3), remove four screws (15),
four lockwashers (16), four flat washers (17), and hydraulic
motor (3) from support bracket (14). Discard lockwashers. Cut
and discard lockwire.
Cut and discard lockwasher (18).
Remove four screws (19) and four lockwashers (20) to remove
support bracket (14), foot brake assembly (21 ) and carrier
assembly (22) as an assembly from roller assembly (23). Have
helper assist to move assembly to suitable workplace. Discard
lockwashers.
Remove spring (24) and position foot pedal (25) to remove screw
(26), lockwasher (27), flat washer (28) and nut (29), and remove
foot brake assembly (21) from support bracket (14). Discard
lockwasher.
Slide carrier assembly (22) off support bracket (14).