TM   9-2350-267-10 Table  2-1.  Preventive  Maintenance  Checks  and  Services  for  Model  M992 Item No. 42 43 Interval Weekly Weekly Location Item  to Check/ Service Lights Continued Bilge Pumps Crewmember Procedure DRIVER WARNING Do not look directly into infrared lights. You may damage  your  eyes. Do not touch lens. You may  burn  your  fingers. f. Check infrared lights on both high and low beam. Do this by HOLDING   YOUR   HANDS OVER THE LENS, but do not touch the lens. If light is operat- ing properly, you will feel heat. DRIVER CAUTION Do not run bilge pumps for  more  than  one  minute dry, or more than 15 min- utes wet without starting engine. Check operation of each bilge pump. If a pump is dry, feel air outlet when pump is running. Not Fully Mission Capable  If: Any bilge pump in- operative  or  miss- ing. 2-64