TM 9-2350-267-10 MAIN ENGINE COLD WEATHER STARTING NOTE Cold weather starting procedures are to be used at 0° F and below.  However,  these  procedures  also  apply  when  vehicle won’t  start  at  32°  F.  Flame  heater  switch  and  starter  switch must be activated at same time. Prestarting Procedure 1. Start APU (APU Starting in Extremely Cold Weather, page 2-221). 2. After APU has been running for 3 minutes, turn APU Generator switch (1 ) ON. 3. After APU has been running for 15 minutes, turn off APU GENerator switch and check BAITERY-GENERATOR indicator gage (2). 4. 5. 6. If  BATTERY-GENERATOR  indicator  gage  indicates  at  least  mid-yellow,  turn APU  GENerator  switch  ON  and  attempt  cold  weather  engine  start  according to procedure on page 2-219. If  BATTERY-GENERATOR  indicator  gage  indicates  less  than  mid-yellow, turn APU GENerator switch ON again and continue charging batteries before starting. Periodically check BATTERY-GENERATOR indicator gage by turning APU GENerator  switch  OFF.  When  gage  indicates  mid-yellow  or  better,  com- mence  cold  weather  start  (page  2-219). 2-218