TM   9-2350-267-10 VENTILATED FACE PIECE SYSTEM (VFPS) - Continued Maintenance WARNING Crew members are not authorized to change con- taminated  filters. 1. Notify Organizational Maintenance to change M12A1 gas filter and/or Ml 3 particulate filter when one or more of the following conditions are observed: Physical damage Water immersion Low air flow to face pieces 5,000-mile vehicle overhaul (peacetime operation) 10,000 hours of vehicle operation (no chemical agents used - wartime operation) 1500 hours (approximately 5 months) of vehicle operation (chemical agents used  -  wartime  operation) After each CK (cyanagen chloride - a blood agent) attack At beginning of combat conditions and when use of CK is expected. 2. Notify Organizational Maintenance to replace spring clip if: Clip is missing or damaged. Rubber gasket is missing or does not seal properly. PREPARATION FOR MOVEMENT Before moving the M992, check to see that all systems and cargo compartments are secured for travel. The following steps present specific items to be checked before moving. 1. Make sure conveyor and stacker are properly stowed and secured (p 2-165 and  2-171). 2-206