TM 9-2350-261-34
10.
11.
12.
13.
14.
NOTE
Both inverters are removed the same
way.
Remove three screws (1) and
lockwashers (2) from mount (3) and
16. Remove three screws (20), mounting
strip (21), inverter housing (6), and retain-
tray (4). Discard lockwashers.
ing strip (22) from sponson.
Remove mount (3) and inverter (5), from
housing (6). Have Helper assist.
Remove four screws (7), washers (8),
locknuts (9), and mount (3) from
inverter (5). Discard locknuts.
Remove four screws (10), lockwashers (11),
and tray (4) from four resilient mounts (12).
Discard lockwashers.
Remove sixteen screws (13), locknuts (14),
thirty-two washers (15), and four
straps (16) from tray (4). Discard locknuts.
15. Remove eight locknuts (17). washers (18),
screws (19), and four resilient mounts (12),
from housing (6). Discard locknuts.
GO TO NEXT PAGE
Change 4
21.1-11