TM 9-2350-261-34
R E M O V E C A B LE
NOTE
Use same procedure for repairing single
or multiple lead, and male or female cable
connectors.
10.
11.
12.
13.
14.
Loosen retaining nut (1) from plug (2). Slide
nut back on cable (3).
Pull grommet (4) with contacts (5) from
rear of plug (2).
Remove plug (2) and coupling nut (6) from
cable (3).
Push leads of cable (3) into grommet (4)
until contacts (5) are fully exposed on other
side of grommet. Clip or desolder leads from
contacts. Discard contacts.
Remove grommet (4) and retaining nut (1)
from cable (3).
18.
19.
Solder leads in contacts (5) and press con-
tacts into grommet (4). Check leads for re-
sistance. Use multimeter.
Aline and install grommet (4) in plug (2).
secure with retaining nut (1).
INSTALL CABLE
NOTE
If replacing lead, cut new wire from bulk
supply. Measure original length, gage,
and type of wire.
15. Strip insulation from leads of cable (3) to
uncover just enough wire to fill well in
contact (5).
16. Slide retaining nut (1) and coupling nut (6)
on cable (3).
17. Push leads of cable (3) through grommet (4)
and insert in new contacts (5).
NOTE
Make sure leads pass through proper
lettered hole in grommet.
END OF TASK
Change 4
6-67 (6-68 blank) (6-69 thru 6-138 deleted)