TM 9-2350-261-20-4
REPLACE CABLE W45 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Personnel Required
Maintenance Level
Power-Generation Equipment Repairer 52D10
Unit
Equipment Condition
Tools and Special Tools
Engine stopped (see your -10)
Carrier blocked (see your -10)
Materials/Parts
All external power disconnected (TM 11-7010-256-
Tie strap (6)
12&P)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect cable plug W45 P1 (1) from DC power extension box jack A9 J2 (2).
2.
Disconnect cable plug W45 P13 (3) from power control enclosure jack A1 J33 (4).
3.
Remove six tie straps (5) from cables. Discard tie straps.
4.
Remove screw (6) and clamp (7) from cables.
5.
Remove three screws (8) and clamps (9) from cables. Remove cable W45 (10) from carrier.