TM 9-2350-261-20-4
REPLACE AC POWER EXTENSION BOX A6 AND DC POWER
EXTENSION BOX A9 AND MOUNT (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Locknut (8)
Personnel Required
Power-Generation Equipment Repairer 52D10
REMOVAL
1.
Disconnect UPS cable W42 (1) from connector (2) on DC power extension box (3).
Disconnect UPS cable W43 (4) from connector (5) on AC power extension box (6).
2.
3.
Disconnect cable W10 (7) from connector (8) on DC power extension box (3).
4.
Disconnect cable W45 (9) from connector (10) on DC power extension box (3).
Disconnect cable W7 (11) from connector (12) on AC power extension box (6).
5.
6.
Remove eight locknuts (13), screws (14), and two power extension boxes (3) and (6) from mount (15). Discard locknuts.
7.
Remove four screws (16), washer (17), and mount (15) from work station (18).