TM 9-2350-261-20-4
REPLACE POWER CONTROL ENCLOSURE ASSEMBLY A1 (M1068 ONLY)
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Equipment Condition
Maintenance Level
Engine stopped (see your -10)
Unit
Carrier blocked (see your -10)
Tools and Special Tools
All external power disconnected (TM 11-7010-256-
12&P)
Battery ground lead disconnected (WP 0294 00)
Materials/Parts
Lockwasher (2)
Personnel Required
Power-Generation Equipment Repairer 52D10
Helper (H)
REMOVAL
1.
Remove two screws (1), lockwashers (2), and bracket (3) from power control enclosure (4). Discard lockwashers.
NOTE
Tag all cables/connectors before removal for proper installation later.
2.
Disconnect all cables/connectors (5) from left and right sides of power control enclosure (4).
3.
Remove eight screws (6), washers (7), and power control enclosure (4) from inverter housing (8). Have helper assist.